The valved version of 3M’s Aura flat-fold respirator, for dusty work where you expect to keep the mask on for hours rather than minutes: grinding, sanding, sweeping, bagging, clearing out a loft or a flood-damaged room. The three panels open into a shape that follows the nose and chin rather than pressing flat against the face, which is what makes it tolerable for a long stretch, and the sculpted top panel leaves room for glasses. Each respirator is wrapped individually, so a box stores well and you open one at a time.
Key features
- NIOSH-approved N95, approval number TC-84A-5669, for at least 95% filtration of solid and liquid aerosols that do not contain oil
- 3M Cool Flow comfort exhalation valve, which releases warm, moist breath and reduces heat build-up inside the respirator
- Three-panel flat-fold design that is collapse resistant and leaves room for eyewear
- Adjustable aluminium nose clip and a soft polyurethane nose foam for the seal across the bridge of the nose
- Braided polyisoprene headbands, stapled to the body, with a chin tab that makes positioning easier
- Individually wrapped, and contains no components made from natural rubber latex
Specifications
- Filter class: N95; assigned protection factor of 10 under US OSHA and Canadian CSA rules
- NIOSH approval: TC-84A-5669, under 42 CFR Part 84
- Weight: approximately 0.5 oz (14 g) each
- Shelf life: five years from the date of manufacture, with a use-by date printed on the box
- Storage: between -4 and 86 F (-20 and 30 C), below 80% relative humidity
- Accepted fit-test protocols: saccharin, Bitrex and condensation nuclei counter
A respirator only works if it seals. Facial hair along the sealing surface defeats it, and so does the wrong size or a nose clip that has not been moulded with both hands, so check the seal every time you put one on. This one is approved for particulates only: not for gases or vapours, not for oil aerosols, not for asbestos, arsenic, cadmium, lead or abrasive blasting, and never in an oxygen-deficient space. Note also that an exhalation valve filters what you breathe in but not what you breathe out, so a valved respirator is the wrong choice when the point is to protect other people. 3M labels this as occupational equipment, and workplace use in the United States requires a written respiratory protection programme under OSHA 1910.134 with fit testing and medical evaluation. Finally, a word on labels: a KN95 is certified to a Chinese standard and is not a NIOSH-approved respirator, whatever the listing says, so look for a TC-84A number like the one above.